[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"content:\u002Fconstruction-rfi-template":3},{"path":4,"title":5,"description":6,"h1":7,"kind":8,"updated":9,"calculator":10,"downloads":11,"sections":24,"toc":68,"stats":76,"readingMinutes":77,"related":78,"children":98,"parent":10},"\u002Fconstruction-rfi-template","Construction RFI Template (Word, Excel, PDF) With Examples","Free construction RFI template in Word, with an Excel RFI log and a PDF. Includes 16 electrical RFI examples with ready wording, and tips for getting an answer.","Construction RFI template (Word, Excel, PDF) with electrical examples","template","2026-11-13",null,[12,16,20],{"label":13,"file":14,"size":15},"Download Word (.docx)","\u002Fdownloads\u002Fconstruction-rfi-template.docx","38 KB",{"label":17,"file":18,"size":19},"Download RFI log (.xlsx)","\u002Fdownloads\u002Fconstruction-rfi-log.xlsx","8 KB",{"label":21,"file":22,"size":23},"Download PDF","\u002Fdownloads\u002Fconstruction-rfi-template.pdf","3 KB",[25,29,34,38,42,46,50,64],{"id":26,"title":27,"kind":26,"html":28},"intro","","\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">An RFI, or request for information, is a written question sent to the design team when the drawings or specifications do not give you what you need to build or price the work. This page gives you a Word form, an Excel log to track every RFI, and a PDF of the form. After the template you will find 16 electrical examples with ready wording.\u003C\u002Fp>\n",{"id":30,"title":31,"kind":32,"html":33},"the-template","The template","body","\u003Ch2 id=\"the-template\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">The template\u003C\u002Fh2>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">The Word form has these fields:\u003C\u002Fp>\n\u003Cul class=\"my-5 ml-6 list-disc space-y-2.5 text-lg text-slate-800 marker:text-xl marker:text-accent sm:text-xl\">\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">RFI no.\u003C\u002Fstrong>, \u003Cstrong class=\"font-bold text-slate-900\">project\u003C\u002Fstrong>, \u003Cstrong class=\"font-bold text-slate-900\">date\u003C\u002Fstrong>, \u003Cstrong class=\"font-bold text-slate-900\">to\u003C\u002Fstrong> and \u003Cstrong class=\"font-bold text-slate-900\">from\u003C\u002Fstrong>.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Sheets \u002F details\u003C\u002Fstrong> and \u003Cstrong class=\"font-bold text-slate-900\">grid \u002F location\u003C\u002Fstrong>: where the problem is.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Question\u003C\u002Fstrong>: one question only.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Priced as\u003C\u002Fstrong>: your assumption, which stands until the question is answered.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Suggested solution\u003C\u002Fstrong>: your proposed answer.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Response needed by\u003C\u002Fstrong>.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Cost impact\u003C\u002Fstrong> and \u003Cstrong class=\"font-bold text-slate-900\">schedule impact\u003C\u002Fstrong>: yes or no, with an amount or days.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Response area\u003C\u002Fstrong>: for the design team to answer, sign and date.\u003C\u002Fli>\n\u003C\u002Ful>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">The Excel log has one row per RFI: number, date sent, to, sheet, subject, priced-as, due date, status, date answered, days open (a formula), cost and schedule impact, and a response summary. At the top, formulas count open, answered and closed items and flag overdue ones. The PDF is the same form for printing.\u003C\u002Fp>\n",{"id":35,"title":36,"kind":32,"html":37},"pre-bid-rfi-or-construction-rfi","Pre-bid RFI or construction RFI","\u003Ch2 id=\"pre-bid-rfi-or-construction-rfi\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">Pre-bid RFI or construction RFI\u003C\u002Fh2>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">The two look alike, but the rules differ.\u003C\u002Fp>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">\u003Cstrong class=\"font-bold text-slate-900\">Pre-bid RFIs\u003C\u002Fstrong> go out during bidding. The answer, if it comes, usually arrives as an addendum that every bidder receives. Deadlines are short and often fixed by the bid documents. Ask only what changes your price. If no addendum follows, price your assumption and write it as a clarification in your bid.\u003C\u002Fp>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">\u003Cstrong class=\"font-bold text-slate-900\">Construction RFIs\u003C\u002Fstrong> go out after award. The answer is part of the project record. If the answer adds work beyond what you priced, the RFI is your starting point for a change order: it shows what the drawings said, when you asked, and how you priced it. For the electrical contractor, this is the main reason to write RFIs rather than phone calls. Follow the process in your contract, because it may say who sends RFIs, to whom, and how fast the design team must answer.\u003C\u002Fp>\n",{"id":39,"title":40,"kind":32,"html":41},"sixteen-electrical-rfi-examples","Sixteen electrical RFI examples","\u003Ch2 id=\"sixteen-electrical-rfi-examples\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">Sixteen electrical RFI examples\u003C\u002Fh2>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">These are written in our own words. Most follow question types that came up in our tests of counting devices from real drawing sets; a few, such as plan against spec, are common RFIs on any job. Sheet numbers and details are placeholders. Replace them with yours, and keep the &quot;priced as&quot; line honest.\u003C\u002Fp>\n\u003Col class=\"my-5 ml-6 list-decimal space-y-2.5 text-lg text-slate-800 marker:font-extrabold marker:text-accent-dark sm:text-xl\">\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Fault current above breaker rating.\u003C\u002Fstrong> The one-line shows available fault current higher than the AIC rating of the breakers. Ask: &quot;Sheet E3.01 shows [value] available fault current, but panel [name] breakers are rated [value]. Please confirm required AIC ratings. Priced as: breakers rated per the panel schedule.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Symbol not in the legend.\u003C\u002Fstrong> &quot;The symbol at grid [C\u002F4] on E1.01 is not shown in the legend. Please identify it. Priced as: [device].&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Required by notes but not drawn.\u003C\u002Fstrong> &quot;Keyed note 1 requires time clocks, but none are shown. Please give the quantity and locations. Priced as: one time clock per [area].&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Fan disconnects.\u003C\u002Fstrong> &quot;General note G requires a disconnecting means at each motor. None are drawn at the six exhaust fans. Priced as: no separate disconnects, cord-and-plug or built-in only.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Missing panel schedule.\u003C\u002Fstrong> &quot;Emergency panel [name] is fed on the one-line and has circuits listed on E1.21 but no schedule in the set. Please provide it. Priced as: [size] breakers, feeder per one-line.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">A circuit to a room that does not exist.\u003C\u002Fstrong> &quot;Panel [name] circuit 39 feeds 'counter receptacle, Room 211.' No Room 211 is on the plans. The nearest counter is in Room 210. Priced as: Room 210.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Devices with no circuit.\u003C\u002Fstrong> &quot;Six junction boxes on E1.01 show no circuit number or function. Please give use and circuit. Priced as: box and connection only, with no device.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">New or relocated.\u003C\u002Fstrong> &quot;Fire alarm devices on E1.11 are not marked new or relocated, and the demolition notes allow salvage. How many are reusable? Priced as: all devices new.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Who furnishes fire alarm.\u003C\u002Fstrong> &quot;Is the fire alarm panel and its devices by a separate fire alarm contractor? Priced as: raceway and boxes only, by us. Devices by others.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Furniture feeds.\u003C\u002Fstrong> &quot;Receptacles and boxes tagged 'F' appear at the cubicles. Does the furniture vendor supply the devices, with us supplying only the feed? Priced as: feed and box only.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Wiring method not stated.\u003C\u002Fstrong> &quot;No wiring method is given for the branch circuits on E1.01 or in the spec. Please confirm conduit type. Priced as: EMT in exposed areas, MC cable in stud walls.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">GFCI near sinks drawn inconsistently.\u003C\u002Fstrong> &quot;General note B requires GFCI within six feet of a sink. Two custodial receptacles and one refrigerator receptacle are within that distance but are drawn as standard duplex. Priced as: GFCI at those three.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Plan against spec.\u003C\u002Fstrong> &quot;Sheet E1.01 shows 20 A, 120 V receptacles at the stage; Section 26 27 26 calls for 20 A tamper-resistant GFCI. Which governs? Priced as: spec.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Reference to a sheet that does not exist.\u003C\u002Fstrong> &quot;Keyed note 5 refers to sheet E2.0. The set has E2.01. Please confirm that the grounding detail on E2.01 is meant. Priced as: E2.01.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Quantity the drawings leave open.\u003C\u002Fstrong> &quot;Occupancy sensors are drawn as one symbol per room with a note that the contractor determines quantity. Please give the intended coverage. Priced as: [number] sensors and [number] power packs.&quot;\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Group marks on switches.\u003C\u002Fstrong> &quot;Switch symbols marked 'S3 (a,b,c)' appear on E1.21. We read each as three switches for zones a, b and c. Please confirm. Priced as: three switches each.&quot;\u003C\u002Fli>\n\u003C\u002Fol>\n",{"id":43,"title":44,"kind":32,"html":45},"how-to-write-an-rfi-that-gets-answered","How to write an RFI that gets answered","\u003Ch2 id=\"how-to-write-an-rfi-that-gets-answered\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">How to write an RFI that gets answered\u003C\u002Fh2>\n\u003Cul class=\"my-5 ml-6 list-disc space-y-2.5 text-lg text-slate-800 marker:text-xl marker:text-accent sm:text-xl\">\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">One question per RFI.\u003C\u002Fstrong> A long list gets a partial answer, and the rest sits open.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Point to the place.\u003C\u002Fstrong> Give the sheet, detail, room and grid. Attach a cropped screenshot with the spot marked.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Show your reading.\u003C\u002Fstrong> State what you found, then what is missing. Do not write &quot;unclear&quot;.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Offer a solution.\u003C\u002Fstrong> A yes-or-no question is faster to answer than an open one.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Write the &quot;priced as&quot; line.\u003C\u002Fstrong> It tells the team what happens if they say nothing, and it is your record.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Set a date.\u003C\u002Fstrong> Make it reasonable. Give at least a few working days unless the bid deadline forces less.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Be neutral.\u003C\u002Fstrong> The RFI is not a complaint. Keep it short and polite.\u003C\u002Fli>\n\u003Cli class=\"pl-2\">\u003Cstrong class=\"font-bold text-slate-900\">Log it.\u003C\u002Fstrong> Use the Excel log and follow up before the due date, not after.\u003C\u002Fli>\n\u003C\u002Ful>\n",{"id":47,"title":48,"kind":32,"html":49},"find-the-questions-earlier","Find the questions earlier","\u003Ch2 id=\"find-the-questions-earlier\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">Find the questions earlier\u003C\u002Fh2>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">Finding these questions usually takes a slow read through the whole set. Our \u003Ca href=\"\u002Felectrical-takeoff-software\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">electrical takeoff software\u003C\u002Fa> lists the open questions it finds while counting. See real results on the \u003Ca href=\"\u002Fsample-takeoffs\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">sample takeoffs\u003C\u002Fa> page. For symbols and legends, read \u003Ca href=\"\u002Felectrical-blueprint-symbols\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">electrical blueprint symbols\u003C\u002Fa> and \u003Ca href=\"\u002Fhow-to-read-electrical-blueprints\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">how to read electrical blueprints\u003C\u002Fa>. Tie your answers back to the \u003Ca href=\"\u002Felectrical-estimate-template\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">estimate template\u003C\u002Fa> and the \u003Ca href=\"\u002Felectrical-panel-schedule-template\" class=\"font-semibold text-brand-700 underline decoration-accent decoration-2 underline-offset-2 hover:text-accent-dark\">panel schedule template\u003C\u002Fa>.\u003C\u002Fp>\n",{"id":51,"title":52,"kind":51,"html":53,"faq":54},"faq","FAQ","\u003Ch2 id=\"faq\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">FAQ\u003C\u002Fh2>\n",[55,58,61],{"question":56,"html":57},"Who answers an electrical RFI?","\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">Usually the engineer of record or architect, through the general contractor. Send it to whoever your contract names, normally the general contractor.\u003C\u002Fp>\n",{"question":59,"html":60},"Should I send RFIs before bidding?","\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">Yes, for items that change your price and that you cannot reasonably assume. Check the bid documents for the deadline for questions.\u003C\u002Fp>\n",{"question":62,"html":63},"What if no one answers?","\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">Keep the &quot;priced as&quot; line in your bid or contract file, follow up in writing, and note the date. If the final answer changes your cost, use the RFI record to support your change order request.\u003C\u002Fp>\n",{"id":65,"title":66,"kind":65,"html":67},"sources","Sources","\u003Ch2 id=\"sources\" class=\"mt-0 mb-6 text-3xl font-extrabold tracking-tight text-brand-950 scroll-mt-28 before:mb-4 before:block before:h-1.5 before:w-14 before:rounded-full before:bg-accent sm:text-4xl\">Sources\u003C\u002Fh2>\n\u003Cul class=\"my-5 ml-6 list-disc space-y-2.5 text-lg text-slate-800 marker:text-xl marker:text-accent sm:text-xl\">\n\u003Cli class=\"pl-2\">Wikipedia, &quot;Request for information&quot;: general definition of an RFI, including its construction use.\u003C\u002Fli>\n\u003C\u002Ful>\n\u003Cp class=\"my-5 text-lg leading-relaxed text-slate-800 sm:text-xl sm:leading-relaxed\">Contract rules for RFIs vary. Your contract documents, or a licensed attorney, decide your deadlines and your right to a change order.\u003C\u002Fp>\n",[69,70,71,72,73,74,75],{"id":30,"title":31},{"id":35,"title":36},{"id":39,"title":40},{"id":43,"title":44},{"id":47,"title":48},{"id":51,"title":52},{"id":65,"title":66},[],6,[79,84,89,94],{"path":80,"h1":81,"description":82,"kind":83},"\u002Felectrical-takeoff-software","Electrical takeoff software: what you get from a PDF drawing set","What the takeoff gives you from a PDF electrical drawing set: counted devices by sheet, a mark on the drawing for each one, open items and a CSV with named columns.","product",{"path":85,"h1":86,"description":87,"kind":88},"\u002Fsample-takeoffs","Sample electrical takeoffs from public bid sets","Three example electrical takeoffs from public bid sets: a park restroom, an office renovation and a scanned music stage set. See how to read each takeoff.","hub",{"path":90,"h1":91,"description":92,"kind":93},"\u002Felectrical-blueprint-symbols","Electrical blueprint symbols on construction plans","Plain-words guide to the symbols on commercial electrical plans: receptacles, switches, S3 and (a,b,c) groups, fixtures, panels, home runs and circuit tags.","guide",{"path":95,"h1":96,"description":97,"kind":93},"\u002Fhow-to-read-electrical-blueprints","How to read electrical blueprints","How to read commercial electrical blueprints: sheet index, legend, notes, panel schedules, one-line diagram, plans, demolition, new vs existing, load checks.",[]]